Open channel flowmeter
-
The dBMACH3 ultrasonic sensor is specially designed for open channel flow measurement. Excellent shading and anti-immersion covers are specially designed to ensure ultra-high precision. It is a 0 blind zone ultrasonic sensor, this Ultra3 is specially designed for open channel flow. Mainly used in sewage treatment plants, as well as other enterprises and institutions of the outlet open channel flow measurement. The most significant advantage of ultrasound is non-contact and has higher reliability than other types of measuring instruments. Ultra3 is used in conjunction with the tank weir, using ultrasonic sensors to measure the level of the liquid level in the tank weir, and calculate the flow rate according to the level height. dBMACH3 special ultrasonic sensor can be used in conjunction with Ultra3 to achieve 0.25mm resolution and 1mm measurement accuracy. Technical parameters: The sensor can be installed only a few millimeters from the highest liquid level, thus ensuring the measurement accuracy.
Order code: 930004
Normal delivery period: 4-6 weeks, subject to the contract
Origin: UK -
-
Size193*155*102mm
-
Weight1Kg
-
Housing materialPolycarbonate (PC)
-
Cable size1000m
-
Protection levelIP65 outer
-
Operating temperatur-20 to 70°C, 0 to 95% relative humidity, no condensation
-
Measurement accuracy+/- 1mm
-
Resolution0.25mm
-
Measuring range0-2.425m
-
Digital communicatioRS232
-
DisplayLCD
-
Power supply115VAC/230VAC
-
InstallationWall mounting or cabinet installation
-