TurbiTechw2 HR high range sludge concentration meter
-
The TurbiTechw2 HR sensor is more suitable for monitoring applications with higher concentration of solid particles than LA, due to the shorter infrared channel length of the sensor. The larger optical measurement surface and sample measurement ensure that the sensor can provide true and reliable information to reflect the content of solid particles in the processing process. The dirt and grease deposited on the sensor will not prevent the sensor from giving accurate readings, which is incomparable to other sensors with only a small measurement area.
The sensor has a set of mechanical automatic cleaning system, which can ensure that the optical measurement surface is kept clean. The cleaning system is designed to avoid the troubles caused by textile entanglement, etc., without soiling the optical measurement system. No routine maintenance is required. We have 46 years of sensor production experience, and the mechanical automatic cleaning system has been successfully used for 25 years, which is incomparable to other types of cleaning methods.
- membrane biochemical pool
- mixed liquid
- return sludge
- excess sludge
860nm infrared light absorption method
- automatic cleaning
- larger measurement area
- supernormal service life (design life 10 years)
No need for any maintenance, no maintenance Chen Ben
More stable measurements, more accurate readings
7300
the actual measurement range of the optical sensor depends on the actual sample particle shape, diameter, color, etc.
Order code: 223882
Normal delivery period: 4-6 weeks (for reference only), subject to the contract
Origin: UK -
-
Size80mm(Diameter)x 470(Length) mm
-
Weight2.2 kg (Including 10m cable)
-
Protection levelDetector: IP68, maximum depth of 2 m (underwater type) Transmitter: IP65 (jetproof type) Pollution degree 2
-
Housing materialStainless steel (1.4571/1.4404) or titanium (3.7035)
-
Contact with water1.316 Stainless steel, glass
-
Sealing materialNitrile
-
Cable typeFour core, twisted, anti-corrosion, high temperature
-
Cable size10m standard, 100m longest
-
Maintenance intervalReplace the cleaning seal around 5-6 years (depending on the cleaning cycle setting)
-
Operating temperatur-20 to 70°C
-
Storage temperature-20 to 60°C
-
PositionIndoor/outdoor
-
Measurement accuracyBetter than 5%
-
Resolution+/-2% Depending on the setting range
-
RepeatabilityBetter than +/-1%
-
Measuring principleOptical principle
-
Wavelength860 nm Infrared light
-
Response time0.2s
-
Allow overpressure10m
-
Flow rateWill not be affected by the flow rate, but avoid static points and excessive fluctuations
-
Maximum range0 - 30,000 mg/l
-
Minimum range0 - 10,000 mg/l
-